Retail Strip Parking Lot Lighting Case Study

The following parking lot lighting project showcases a security-focused lighting upgrade for a retail strip center located in a high-crime area. The client prioritized safety and visibility for customers and employees during nighttime hours, seeking a solution that could deter criminal activity while also enhancing the shopping experience.

Retail Parking Lot Lighting Design

To meet these demands, we provided a complete photometric layout and recommended high-output 180W LED area lights with Type IV optics. These fixtures were installed along both the front and rear building façades to deliver consistent and powerful coverage across the entire lot.

Results

Front Parking Lot (70 ft x 150 ft):

  • Fixture: 180W LED Area Light, Type IV Lens
  • Fixture Count: 5 units
  • Mounting Height: Approx. 15–20 feet
  • Average Illumination: 5.4 footcandles
  • Maximum Illumination: 14.3 footcandles
  • Minimum Illumination: 0.90 footcandles
  • Fixture Certifications: DLC Premium, UL Listed, IP65 Rated

Rear Parking Lot (65 ft x 80 ft):

  • Fixture: 180W LED Area Light, Type IV Lens
  • Fixture Count: 3 units
  • Mounting Height: Approx. 15–20 feet
  • Average Illumination: 5.1 footcandles
  • Maximum Illumination: 11.5 footcandles
  • Minimum Illumination: 0.8 footcandles
  • Fixture Certifications: DLC Premium, UL Listed, IP65 Rated

The upgraded lighting system dramatically enhanced nighttime visibility across both the front and rear lots, achieving industry-recommended illumination levels for retail and security applications. By eliminating shadowy zones and maintaining consistent brightness, the solution helped deter criminal activity and made customers feel safer while shopping at night.